{"product_id":"alpha-vertical-flue-terminal-1m-6-2000520","title":"Alpha CD Vertical Flue Terminal with 1m Flue 60\/100mm 6.2000520","description":"\u003ch2\u003eAlpha CD Vertical Flue Terminal with 1m Flue (60\/100mm) 6.2000520\u003c\/h2\u003e\n\u003cp\u003eGenuine Alpha concentric 60\/100mm vertical flue terminal assembly, supplied with a 1000mm flue section. It is designed for roof (vertical) flueing of Alpha CD and HE condensing boilers and must only be used with those boilers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFits these boilers:\u003c\/strong\u003e \u003ca href=\"\/products\/alpha-e-tec-nx-combi-boiler\"\u003eAlpha E-Tec NX combi boiler 28–33kW\u003c\/a\u003e, \u003ca href=\"\/products\/alpha-e-tec-plus-nx-combi-boiler\"\u003eAlpha E-Tec Plus NX combi boiler 28–38kW\u003c\/a\u003e, \u003ca href=\"\/products\/alpha-evoke-nx-combi-boiler\"\u003eAlpha Evoke NX combi boiler 28–33kW\u003c\/a\u003e, \u003ca href=\"\/products\/alpha-e-tec-nxs-system-boiler\"\u003eAlpha E-Tec NXS system boiler 20–35kW\u003c\/a\u003e, \u003ca href=\"\/products\/alpha-e-tec-regular-boiler\"\u003eAlpha E-Tec regular (heat only) boiler 15–25kW\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey points\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlpha part number 6.2000520 (also listed as 6.200052)\u003c\/li\u003e\n\u003cli\u003eConcentric 60\/100mm flue system, white\u003c\/li\u003e\n\u003cli\u003eTerminal assembly with 1000mm flue length\u003c\/li\u003e\n\u003cli\u003eFor Alpha CD and HE condensing boilers only\u003c\/li\u003e\n\u003cli\u003eTerminal counts as 1m of equivalent flue length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVertical flue terminal assembly with 1m flue\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA roof weathering slate is not included: use Alpha \u003ca href=\"\/products\/alpha-pitched-roof-flashing-slate-6-1000380\"\u003e6.1000380 (pitched roof)\u003c\/a\u003e or 6.1000390 (flat roof).\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e6.2000520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlue system\u003c\/th\u003e\n\u003ctd\u003eConcentric 60\/100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e1000mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eColour\u003c\/th\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax equivalent flue length (inc. terminal)\u003c\/th\u003e\n\u003ctd\u003eCD boilers 15m, HE boilers 6m (current NX and E-Tec R boilers: 14m, see the boiler manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquivalent length of bends\u003c\/th\u003e\n\u003ctd\u003e45° 0.9m, 90° 1.3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRoof opening\u003c\/th\u003e\n\u003ctd\u003eMinimum 150mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e£119.99 inc VAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlue extensions: 750mm (6.2000750) and \u003ca href=\"\/products\/alpha-concentric-flue-extension-1000mm-6-2001050\"\u003e1000mm (6.2001050)\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlue support bracket 6.1000355 (support roughly every 1.5m)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/alpha-pitched-roof-flashing-slate-6-1000380\"\u003ePitched roof flashing slate 6.1000380\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; compliance\u003c\/h3\u003e\n\u003cp\u003eMust be installed by a Gas Safe registered engineer in line with the Alpha instructions, the boiler manual and BS 5440-1. Keep at least 25mm between the outer duct and any combustible material, and check the maximum flue length for your boiler model before ordering.\u003c\/p\u003e\n\u003ch3\u003eDelivery \u0026amp; collection\u003c\/h3\u003e\n\u003cp\u003eFree UK delivery on orders over £50 (£4.99 under £50). Free collection from our Lincoln unit, usually ready within 24 hours.\u003c\/p\u003e\n\u003cp\u003eManufacturer installation instructions are in the PDF downloads at the bottom of this page.\u003c\/p\u003e\n\u003cdiv class=\"shop-the-range\"\u003e\n\u003ch3\u003eShop the range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/alpha-pitched-roof-flashing-slate-6-1000380\"\u003eAlpha Pitched Roof Flashing Slate 6.1000380\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/alpha-concentric-flue-extension-1000mm-6-2001050\"\u003eAlpha Concentric Flue Extension 1000mm 60\/100mm\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/alpha-premierpack-pro-3-028421\"\u003eAlpha PremierPack Pro Boiler Jig with Cyclone Plus Filter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/alpha\"\u003eAll Alpha boilers and accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/boilers\"\u003eBoilers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/heating-equipment\"\u003eHeating Equipment\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Alpha","offers":[{"title":"Default Title","offer_id":45610350870819,"sku":"PLUMHEAT1204","price":119.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/6344\/2467\/products\/PLUMHEAT1204.jpg?v=1690381080","url":"https:\/\/shop.the-glow-group.co.uk\/products\/alpha-vertical-flue-terminal-1m-6-2000520","provider":"The Glow Group","version":"1.0","type":"link"}