{"product_id":"flowcyl-heat-pump-unvented-hot-water-cylinder","title":"UK Cylinders FlowCyl Heat Pump Unvented Hot Water Cylinder 120L–600L","description":"\u003cdiv class=\"availability-notice\" style=\"border:2px solid #e68a2e;border-radius:6px;padding:12px 16px;margin:0 0 16px 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eAvailability: please read before ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCylinders are delivered direct to site from the manufacturer, UK Cylinders. Popular standard sizes are usually available from stock, but some sizes and specifications are \u003cstrong\u003emade to order\u003c\/strong\u003e, so the lead time depends on the cylinder you choose.\u003c\/p\u003e\n\u003cp\u003eAfter you order, we check availability with UK Cylinders and contact you with an estimated delivery date. If your cylinder needs to be made to order, we will confirm the lead time with you first and only place the order once you are happy with it. If it does not suit, you can cancel for a full refund.\u003c\/p\u003e\n\u003cp\u003eOnce a made-to-order cylinder has been confirmed with you and placed with UK Cylinders, the order cannot be cancelled. We arrange the delivery for you.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch2\u003eFlowCyl Heat Pump Unvented Hot Water Cylinder\u003c\/h2\u003e\u003cp\u003eFlowCyl heat pump cylinder with a large-surface, high-gain 1\" coil designed for the low flow temperatures of air and ground source heat pumps. It is compatible with any make of heat pump.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e1mm duplex stainless steel inner vessel\u003c\/li\u003e\n\u003cli\u003eOperating pressure 3 bar, test pressure 8 bar\u003c\/li\u003e\n\u003cli\u003eAluzinc grey casing\u003c\/li\u003e\n\u003cli\u003e25-year cylinder warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKit supplied\u003c\/h3\u003e\u003cp\u003e3 bar\/6 bar inlet control set, 15mm x 22mm tundish, 9 bar\/70°C T\u0026amp;P relief valve, T\u0026amp;P cover, 28mm 2-port valve and high limit cut-out thermostat, plus a 3kW immersion heater (two on 400L and above).\u003c\/p\u003e\u003cp\u003eConnections: 3\/4\" compression hot draw, cold feed and secondary return; 1\" F heat pump flow and return; 1 3\/4\" F immersion boss; 1\/2\" F T\u0026amp;P valve. 12mm sensor pocket.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHeight (mm)\u003c\/th\u003e\n\u003cth\u003eDiameter (mm)\u003c\/th\u003e\n\u003cth\u003eCoil area (m²)\u003c\/th\u003e\n\u003cth\u003eHeat loss (kWh\/24h)\u003c\/th\u003e\n\u003cth\u003eSec. return\u003c\/th\u003e\n\u003cth\u003eErP\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e120L\u003c\/td\u003e\n\u003ctd\u003eFCHPD3120\u003c\/td\u003e\n\u003ctd\u003e945\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e1.61\u003c\/td\u003e\n\u003ctd\u003e1.06\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e150L\u003c\/td\u003e\n\u003ctd\u003eFCHPD3150\u003c\/td\u003e\n\u003ctd\u003e1130\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e2.08\u003c\/td\u003e\n\u003ctd\u003e1.22\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e180L\u003c\/td\u003e\n\u003ctd\u003eFCHPD3180\u003c\/td\u003e\n\u003ctd\u003e1314\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e2.08\u003c\/td\u003e\n\u003ctd\u003e1.47\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200L\u003c\/td\u003e\n\u003ctd\u003eFCHPD3200\u003c\/td\u003e\n\u003ctd\u003e1444\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e2.97\u003c\/td\u003e\n\u003ctd\u003e1.55\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250L\u003c\/td\u003e\n\u003ctd\u003eFCHPD3250\u003c\/td\u003e\n\u003ctd\u003e1752\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e2.97\u003c\/td\u003e\n\u003ctd\u003e1.85\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300L\u003c\/td\u003e\n\u003ctd\u003eFCHPD3300\u003c\/td\u003e\n\u003ctd\u003e1975\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e2.97\u003c\/td\u003e\n\u003ctd\u003e2.02\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400L\u003c\/td\u003e\n\u003ctd\u003eFCHPD4400\u003c\/td\u003e\n\u003ctd\u003e1640\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e2.20\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500L\u003c\/td\u003e\n\u003ctd\u003eFCHPD4500\u003c\/td\u003e\n\u003ctd\u003e1995\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e2.42\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600L\u003c\/td\u003e\n\u003ctd\u003eFCHPD4600\u003c\/td\u003e\n\u003ctd\u003e2190\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e2.68\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eFull dimensions and tapping heights are in the FlowCyl datasheet below.\u003c\/p\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cp\u003eUnvented hot water systems must be installed by a G3-qualified installer and registered with Building Control or a competent person scheme.\u003c\/p\u003e\u003ch3\u003eDelivery\u003c\/h3\u003e\u003cp\u003eDelivered direct to site from UK Cylinders on a pallet, kerbside, to mainland UK addresses. Lead times depend on stock and whether your cylinder needs to be made to order; we will confirm your estimated delivery date after ordering. Please check the cylinder for damage on delivery and note any damage on the delivery paperwork before signing.\u003c\/p\u003e\u003cdiv class=\"shop-the-range\"\u003e\n\u003ch3\u003eShop the UK Cylinders range\u003c\/h3\u003e\n\u003cp\u003ePair it with a \u003ca href=\"\/collections\/samsung-air-source-heat-pumps\"\u003eSamsung air source heat pump\u003c\/a\u003e and a \u003ca href=\"\/products\/flowcyl-buffer-vessel\"\u003eFlowCyl buffer vessel\u003c\/a\u003e, or see our complete \u003ca href=\"\/collections\/heat-pump-packs\"\u003eheat pump packages\u003c\/a\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/flowcyl-heat-pump-pre-plumbed-unvented-hot-water-cylinder\"\u003eUK Cylinders FlowCyl heat pump pre-plumbed cylinder 150L–300L\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/flowcyl-buffer-vessel\"\u003eUK Cylinders FlowCyl heat pump buffer vessel 50L–600L\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/flowcyl-direct-unvented-hot-water-cylinder\"\u003eUK Cylinders FlowCyl direct unvented cylinder 90L–300L\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/flowcyl-indirect-unvented-hot-water-cylinder\"\u003eUK Cylinders FlowCyl indirect unvented cylinder 90L–300L\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/elite-cyl-system-pre-plumbed-twin-zone-unvented-cylinder\"\u003eUK Cylinders Elite pre-plumbed twin zone cylinder 120L–300L\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all \u003ca href=\"\/collections\/uk-cylinders\"\u003eUK Cylinders products\u003c\/a\u003e, \u003ca href=\"\/collections\/heat-pump-cylinders-buffers\"\u003eheat pump cylinders \u0026amp; buffers\u003c\/a\u003e or \u003ca href=\"\/collections\/unvented-hot-water-cylinders\"\u003eunvented hot water cylinders\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"FlowCyl","offers":[{"title":"120L","offer_id":57051003748736,"sku":"PLUMHEAT2210","price":983.99,"currency_code":"GBP","in_stock":true},{"title":"150L","offer_id":57051003781504,"sku":"PLUMHEAT2211","price":1047.99,"currency_code":"GBP","in_stock":true},{"title":"180L","offer_id":57051003814272,"sku":"PLUMHEAT2212","price":1088.99,"currency_code":"GBP","in_stock":true},{"title":"200L","offer_id":57051003847040,"sku":"PLUMHEAT2213","price":1130.99,"currency_code":"GBP","in_stock":true},{"title":"250L","offer_id":57051003879808,"sku":"PLUMHEAT2214","price":1181.99,"currency_code":"GBP","in_stock":true},{"title":"300L","offer_id":57051003912576,"sku":"PLUMHEAT2215","price":1272.99,"currency_code":"GBP","in_stock":true},{"title":"400L","offer_id":60146487099776,"sku":"PLUMHEAT2219","price":2217.99,"currency_code":"GBP","in_stock":true},{"title":"500L","offer_id":60146487132544,"sku":"PLUMHEAT2220","price":2451.99,"currency_code":"GBP","in_stock":true},{"title":"600L","offer_id":60146487165312,"sku":"PLUMHEAT2221","price":2833.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/6344\/2467\/files\/FlowCylHeatPumpCylinder_94a56986-6cfb-497c-bc67-f7cb8576d7dd.png?v=1792324432","url":"https:\/\/shop.the-glow-group.co.uk\/products\/flowcyl-heat-pump-unvented-hot-water-cylinder","provider":"The Glow Group","version":"1.0","type":"link"}